| Rolling Stock Cables | ||||||||||||||||||
|
||||||||||||||||||
FIREROL Thin Wall Multipair Individually Screened and Sheathed
Cables with Standard Wall Overall Sheath
300/500 V
EN 50306-4 (FRL-TW-05MP-SW-IS)

A.Conductor B.Insulation+Pair Screen & Sheath C.Outer Sheath
Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,
where space and weight are an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor: Tinned annealed copper wires as defined in EN 50306-2
Insulation: LSZH special compound
Pair Screen: Individual screened and sheathed; Screened according to EN 50306-3; Sheathed according to EN
50306-3 (S1. S2)
Pair Identification
Pairs numbered according to EN 50306-4
Outer Sheath
LSZH special compound (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V
Max. Conductor Temperature 90 °C/105 °C (fixed installation)
Min. Permissible Ambient Temperature -25 °C/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone
Fire Performance for Rolling Stock Application
EN 50306-2 Hazard levels HL1, HL2, HL3
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2 R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in General
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propagation for a single insulated wire or
cable EN 50266-2-4 + EN 50305; IEC 60332-3-24; Vertical flame spread of vertically mounted bunched wires
or cables NF C 32-070 2.2 (C1); VDE 0472 Teil 804
EN 50268-2; IEC 61034-2; NF C 32-073 ; Low Smoke Emission NF C 20-902; NF F 16 101; VDE 0472 Teil 816
EN 50267-2-1; IEC 60754-1; NF C 32-074; Halogen Free
NF C 20-454; VDE 0472 Teil 815
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; Low Corrosivity (Acidity & Conductivity) NF C 20-453; VDE 0472
Teil 813
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101 Smoke Index
EN45545-2 Requirement for fire behavior of materials & components
R15/R16
FRL-TW-05MP-SW-IS 300/500 V
Number of Pairs and Nominal Cross Section |
Min. Thickness of Sheath at |
Overall Diameter |
Weight |
|
|---|---|---|---|---|
Min. |
Max. |
|||
N x n x mm2 |
mm |
mm |
mm |
kg/km |
2 x 2 x 0.5 |
0.56 |
9.0 |
10.2 |
90 |
3 x 2 x 0.5 |
0.56 |
9.6 |
10.8 |
120 |
4 x 2 x 0.5 |
0.56 |
10.7 |
11.9 |
160 |
7 x 2 x 0.5 |
0.56 |
13.0 |
14.2 |
240 |
|
||||
2 x 2 x 0.75 |
0.56 |
9.8 |
11.0 |
90 |
3 x 2 x 0.75 |
0.56 |
10.5 |
11.7 |
150 |
4 x 2 x 0.75 |
0.56 |
11.6 |
12.8 |
180 |
7 x 2 x 0.75 |
0.56 |
14.0 |
15.6 |
290 |
|
||||
2 x 2 x 1.0 |
0.56 |
10.2 |
11.6 |
110 |
3 x 2 x 1.0 |
0.56 |
10.9 |
12.1 |
160 |
4 x 2 x 1.0 |
0.56 |
12.1 |
13.3 |
200 |
7 x 2 x 1.0 |
0.56 |
14.6 |
16.2 |
330 |
|
||||
2 x 2 x 1.5 |
0.56 |
12.2 |
13.4 |
150 |
3 x 2 x 1.5 |
0.56 |
13.1 |
14.3 |
230 |
4 x 2 x 1.5 |
0.56 |
14.3 |
15.9 |
290 |
7 x 2 x 1.5 |
0.56 |
17.6 |
19.2 |
490 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information