Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

 FIREROL Thin Wall Multipair Individually Screened and Sheathed Cables with Standard Wall Overall Sheath 300/500 V

EN 50306-4 (FRL-TW-05MP-SW-IS)

Rolling Stock Cables

A.Conductor      B.Insulation+Pair Screen & Sheath       C.Outer Sheath

Application

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,

where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor: Tinned annealed copper wires as defined in EN 50306-2

Insulation: LSZH special compound

Pair Screen: Individual screened and sheathed; Screened according to EN 50306-3; Sheathed according to EN

50306-3 (S1. S2)

Pair Identification

Pairs numbered according to EN 50306-4

Outer Sheath

LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V

Max. Conductor Temperature 90 °C/105 °C (fixed installation)

Min. Permissible Ambient Temperature       -25 °C/-40 °C (fixed installation)

Bending Radius  10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2  No fluorine

EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali

EN 50305     Resistance to ozone

Fire Performance for Rolling Stock Application

EN 50306-2  Hazard levels HL1, HL2, HL3

DIN 5510-2   Protection level 1/2/3/4

BS 6853       Interior use 1a, 1b, II; Exterior use 1a, 1b, II

NF F 16-101 F0

EN45545-2   R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in General

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)     Vertical flame propagation for a single insulated wire or

cable EN 50266-2-4 + EN 50305; IEC 60332-3-24;     Vertical flame spread of vertically mounted bunched wires

or cables NF C 32-070 2.2 (C1); VDE 0472 Teil 804

EN 50268-2; IEC 61034-2; NF C 32-073 ;   Low Smoke Emission NF C 20-902; NF F 16 101; VDE 0472 Teil 816

EN 50267-2-1; IEC 60754-1; NF C 32-074; Halogen Free

NF C 20-454; VDE 0472 Teil 815

EN 50267-2-2/3; IEC 60754-2; NF C 32-074;     Low Corrosivity (Acidity & Conductivity) NF C 20-453; VDE 0472

Teil 813

EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853       Low Toxicity

NF F 63 808; BS6853; NF F 16 101     Smoke Index

EN45545-2   Requirement for fire behavior of materials & components

R15/R16

FRL-TW-05MP-SW-IS 300/500 V

Number of Pairs and Nominal Cross Section

Min. Thickness of Sheath at
any Point

Overall Diameter

 

Weight

Min.

Max.

N x n x mm2

mm

mm

mm

kg/km

2 x 2 x 0.5

0.56

9.0

10.2

90

3 x 2 x 0.5

0.56

9.6

10.8

120

4 x 2 x 0.5

0.56

10.7

11.9

160

7 x 2 x 0.5

0.56

13.0

14.2

240

 

2 x 2 x 0.75

0.56

9.8

11.0

90

3 x 2 x 0.75

0.56

10.5

11.7

150

4 x 2 x 0.75

0.56

11.6

12.8

180

7 x 2 x 0.75

0.56

14.0

15.6

290

 

2 x 2 x 1.0

0.56

10.2

11.6

110

3 x 2 x 1.0

0.56

10.9

12.1

160

4 x 2 x 1.0

0.56

12.1

13.3

200

7 x 2 x 1.0

0.56

14.6

16.2

330

 

2 x 2 x 1.5

0.56

12.2

13.4

150

3 x 2 x 1.5

0.56

13.1

14.3

230

4 x 2 x 1.5

0.56

14.3

15.9

290

7 x 2 x 1.5

0.56

17.6

19.2

490

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information