Rolling Stock Cables | ||||||||||||||||||
|
FIREROL Thin Wall Multipair Individually Screened and Sheathed Cables with Standard Wall Overall Sheath 300/500 V
EN 50306-4 (FRL-TW-05MP-SW-IS)
A.Conductor B.Insulation+Pair Screen & Sheath C.Outer Sheath
Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,
where space and weight are an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor: Tinned annealed copper wires as defined in EN 50306-2
Insulation: LSZH special compound
Pair Screen: Individual screened and sheathed; Screened according to EN 50306-3; Sheathed according to EN
50306-3 (S1. S2)
Pair Identification
Pairs numbered according to EN 50306-4
Outer Sheath
LSZH special compound (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V
Max. Conductor Temperature 90 °C/105 °C (fixed installation)
Min. Permissible Ambient Temperature -25 °C/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone
Fire Performance for Rolling Stock Application
EN 50306-2 Hazard levels HL1, HL2, HL3
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2 R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in General
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propagation for a single insulated wire or
cable EN 50266-2-4 + EN 50305; IEC 60332-3-24; Vertical flame spread of vertically mounted bunched wires
or cables NF C 32-070 2.2 (C1); VDE 0472 Teil 804
EN 50268-2; IEC 61034-2; NF C 32-073 ; Low Smoke Emission NF C 20-902; NF F 16 101; VDE 0472 Teil 816
EN 50267-2-1; IEC 60754-1; NF C 32-074; Halogen Free
NF C 20-454; VDE 0472 Teil 815
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; Low Corrosivity (Acidity & Conductivity) NF C 20-453; VDE 0472
Teil 813
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101 Smoke Index
EN45545-2 Requirement for fire behavior of materials & components
R15/R16
FRL-TW-05MP-SW-IS 300/500 V
Number of Pairs and Nominal Cross Section |
Min. Thickness of Sheath at |
Overall Diameter |
Weight |
|
---|---|---|---|---|
Min. |
Max. |
|||
N x n x mm2 |
mm |
mm |
mm |
kg/km |
2 x 2 x 0.5 |
0.56 |
9.0 |
10.2 |
90 |
3 x 2 x 0.5 |
0.56 |
9.6 |
10.8 |
120 |
4 x 2 x 0.5 |
0.56 |
10.7 |
11.9 |
160 |
7 x 2 x 0.5 |
0.56 |
13.0 |
14.2 |
240 |
|
||||
2 x 2 x 0.75 |
0.56 |
9.8 |
11.0 |
90 |
3 x 2 x 0.75 |
0.56 |
10.5 |
11.7 |
150 |
4 x 2 x 0.75 |
0.56 |
11.6 |
12.8 |
180 |
7 x 2 x 0.75 |
0.56 |
14.0 |
15.6 |
290 |
|
||||
2 x 2 x 1.0 |
0.56 |
10.2 |
11.6 |
110 |
3 x 2 x 1.0 |
0.56 |
10.9 |
12.1 |
160 |
4 x 2 x 1.0 |
0.56 |
12.1 |
13.3 |
200 |
7 x 2 x 1.0 |
0.56 |
14.6 |
16.2 |
330 |
|
||||
2 x 2 x 1.5 |
0.56 |
12.2 |
13.4 |
150 |
3 x 2 x 1.5 |
0.56 |
13.1 |
14.3 |
230 |
4 x 2 x 1.5 |
0.56 |
14.3 |
15.9 |
290 |
7 x 2 x 1.5 |
0.56 |
17.6 |
19.2 |
490 |