Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

 FIREROL Thin Wall Multipair Individually Screened and Sheathed Cables with Standard Wall Overall Sheath 300/500 V

EN 50306-4 (FRL-TW-05MP-SW-IS)

Rolling Stock Cables

A.Conductor      B.Insulation+Pair Screen & Sheath       C.Outer Sheath

Application

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,

where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor: Tinned annealed copper wires as defined in EN 50306-2

Insulation: LSZH special compound

Pair Screen: Individual screened and sheathed; Screened according to EN 50306-3; Sheathed according to EN

50306-3 (S1. S2)

Pair Identification

Pairs numbered according to EN 50306-4

Outer Sheath

LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V

Max. Conductor Temperature 90 °C/105 °C (fixed installation)

Min. Permissible Ambient Temperature       -25 °C/-40 °C (fixed installation)

Bending Radius  10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2  No fluorine

EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali

EN 50305     Resistance to ozone

Fire Performance for Rolling Stock Application

EN 50306-2  Hazard levels HL1, HL2, HL3

DIN 5510-2   Protection level 1/2/3/4

BS 6853       Interior use 1a, 1b, II; Exterior use 1a, 1b, II

NF F 16-101 F0

EN45545-2   R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in General

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)     Vertical flame propagation for a single insulated wire or

cable EN 50266-2-4 + EN 50305; IEC 60332-3-24;     Vertical flame spread of vertically mounted bunched wires

or cables NF C 32-070 2.2 (C1); VDE 0472 Teil 804

EN 50268-2; IEC 61034-2; NF C 32-073 ;   Low Smoke Emission NF C 20-902; NF F 16 101; VDE 0472 Teil 816

EN 50267-2-1; IEC 60754-1; NF C 32-074; Halogen Free

NF C 20-454; VDE 0472 Teil 815

EN 50267-2-2/3; IEC 60754-2; NF C 32-074;     Low Corrosivity (Acidity & Conductivity) NF C 20-453; VDE 0472

Teil 813

EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853       Low Toxicity

NF F 63 808; BS6853; NF F 16 101     Smoke Index

EN45545-2   Requirement for fire behavior of materials & components

R15/R16

FRL-TW-05MP-SW-IS 300/500 V

Number of Pairs and Nominal Cross Section

Min. Thickness of Sheath at
any Point

Overall Diameter

 

Weight

Min.

Max.

N x n x mm2

mm

mm

mm

kg/km

2 x 2 x 0.5

0.56

9.0

10.2

90

3 x 2 x 0.5

0.56

9.6

10.8

120

4 x 2 x 0.5

0.56

10.7

11.9

160

7 x 2 x 0.5

0.56

13.0

14.2

240

 

2 x 2 x 0.75

0.56

9.8

11.0

90

3 x 2 x 0.75

0.56

10.5

11.7

150

4 x 2 x 0.75

0.56

11.6

12.8

180

7 x 2 x 0.75

0.56

14.0

15.6

290

 

2 x 2 x 1.0

0.56

10.2

11.6

110

3 x 2 x 1.0

0.56

10.9

12.1

160

4 x 2 x 1.0

0.56

12.1

13.3

200

7 x 2 x 1.0

0.56

14.6

16.2

330

 

2 x 2 x 1.5

0.56

12.2

13.4

150

3 x 2 x 1.5

0.56

13.1

14.3

230

4 x 2 x 1.5

0.56

14.3

15.9

290

7 x 2 x 1.5

0.56

17.6

19.2

490